AREA CODE CHANGEPlease note that the area code forParadyne Corporation in Largo, Floridahas changed from 813 to 727.For any Paradyne telephone number
1-15100-A2-GB20-00November 1996About HotWire DSL1What Is the HotWire 5100 DSL Access System?The HotWire DSL Access System provides high-speed Interne
About HotWire DSL 1-25100-A2-GB20-00November 1996These specific management information bases (MIBs) are supported:— MIB II System and Interface Groups
About HotWire DSL 1-35100-A2-GB20-00November 1996HotWire DSL RequirementsHardware RequirementsHotWire DSL requires an Intel 80486 or Pentium, NEBS-com
2-15100-A2-GB20-00November 1996Installing and Connecting theCard2Package ContentsThe HotWire DSL CO product consists of:H CO DSL cardH HotWire DSL CO
Installing and Connecting the Card 2-25100-A2-GB20-00November 1996In addition to Steps 1–9, a HotWire DSL CP card must be installed in acustomer’s PC
Installing and Connecting the Card 2-35100-A2-GB20-00November 1996Configuration Table for SW1 SwitchesCO PC SlotNumberChannelNumberI/O BaseAddressSwit
Installing and Connecting the Card 2-45100-A2-GB20-00November 1996Setting IRQ Switches to OffIRQ (hardware interrupt request) DIP switch banks SW2 and
Installing and Connecting the Card 2-55100-A2-GB20-00November 1996Connecting the Card to the LAN Network and POTSNetworkThe figure below identifies th
Installing and Connecting the Card 2-65100-A2-GB20-00November 1996Connecting to the LAN NetworkProcedure1. Plug the end of an 8-pin modular cable int
Installing and Connecting the Card 2-75100-A2-GB20-00November 1996P2P3POTS Splitter RackMulti-pinBlock #1Connects toMulti-pinBlock #2496-15026
HOTWIRE 5100 DSLACCESS SYSTEMCENTRAL OFFICEUSER’S GUIDEDocument No. 5100-A2-GB20-00November 1996
Installing and Connecting the Card 2-85100-A2-GB20-00November 1996Four rows of pins of a multi-pin block are dedicated to each CO card/POTSsplitter pa
Installing and Connecting the Card 2-95100-A2-GB20-00November 1996Always connect the CO switch tip and ring leads to the bottom twoA-column pins of a
Installing and Connecting the Card 2-105100-A2-GB20-00November 1996Connecting to the POTS Network Using Standalone POTS SplittersProcedure1. Install
Installing and Connecting the Card 2-115100-A2-GB20-00November 1996Installing the SoftwareThe HotWire DSL CO product software consists of three compon
Installing and Connecting the Card 2-125100-A2-GB20-00November 1996c:\Windows\system32\drivers\genport.sys (orc:\WinNT35\System32\drivers\genport.sys)
3-15100-A2-GB20-00November 1996Accessing the CentralManagement Utility3OverviewThere are three ways to access the CO card in order to configure and m
Accessing the Central Management Utility 3-25100-A2-GB20-00November 1996Accessing the Central Management Utility Locally The procedure that follows de
Accessing the Central Management Utility 3-35100-A2-GB20-00November 19963. From the PC keyboard, type:cd c:\HOTWIREhotwire.exeAlternatively, follow th
Accessing the Central Management Utility 3-45100-A2-GB20-00November 1996Setting the Terminal Interface OptionsThe terminal interface options of the te
Accessing the Central Management Utility 3-55100-A2-GB20-00November 1996Automatically Running the Central ManagementUtilityThe following procedure des
Printed on recycled paper A5100-A2-GB20-00November 1996Copyright 1996 Paradyne Corporation.All rights reserved.Printed in U.S.A.NoticeThis publicati
Accessing the Central Management Utility 3-65100-A2-GB20-00November 199613. Power down the CO PC.14. Disconnect the CO PC monitor and keyboard.15. Pow
4-15100-A2-GB20-00November 1996Configuring and Managing theCard4OverviewThe Hotwire DSL Central Management Utility enables you to configure andmanage
Configuring and Managing the Card 4-25100-A2-GB20-00November 1996Menus That Require InputThe following menus require that you input information (other
Configuring and Managing the Card 4-35100-A2-GB20-00November 1996(The Set Filters menu enables you to configure multiple MAC and IP filter sourceaddre
Configuring and Managing the Card 4-45100-A2-GB20-00November 1996Configuring and Managing the CardThe central management utility enables you to: Moni
Configuring and Managing the Card 4-55100-A2-GB20-00November 1996Operational Status Display (CO) (2 of 2)Parameter DescriptionMAC Broadcast PacketsRec
Configuring and Managing the Card 4-65100-A2-GB20-00November 1996Error Status (CO Cards)The Error Status screen displays the errors related to the ope
Configuring and Managing the Card 4-75100-A2-GB20-00November 1996Error Status (CP Cards)The Error Status screen displays the errors related to the ope
Configuring and Managing the Card 4-85100-A2-GB20-00November 1996Board ID (CO and CP Cards)The Board ID screen shows identifying information about the
Configuring and Managing the Card 4-95100-A2-GB20-00November 1996Diagnostics Display (2 of 2)Parameter DescriptionLoopback Type Loopbacks available to
Important Regulatory Information B5100-A2-GB20-00 November 1996Important Safety Instructions1. Read and follow all warning notices and instructions ma
Configuring and Managing the Card 4-105100-A2-GB20-00November 1996Firmware UpgradeThe Firmware Installation screen enables you download code into the
Configuring and Managing the Card 4-115100-A2-GB20-00November 1996Filters Display (2 of 2)Parameter DescriptionIP Filter Source Address Used to filter
Configuring and Managing the Card 4-125100-A2-GB20-00November 1996Configure DSL CardsThe Configure DSL Card screens enables you to set the data rate o
5-15100-A2-GB20-00November 1996Configuring the SNMP Agent5SNMP Interface ModelThe DSL modem SNMP management model is that of a single CO PC addressed
Configuring the SNMP Agent 5-25100-A2-GB20-00November 1996Configuration After installing the SNMP agent (as described in Chapter 2), you can configure
Configuring the SNMP Agent 5-35100-A2-GB20-00November 1996Up to four destination addresses may be entered. If no destination addresses areentered, no
6-15100-A2-GB20-00November 1996Diagnostics6OverviewHotWire DSL provides you with three ways to monitor the health and status of itscards and connecti
Diagnostics 6-25100-A2-GB20-00November 1996LED StatusThere are 10 LEDs on the CO card.496-1498212345678123456781234TEST SYSTXRXCOLJABTXRXCDLNKEthernet
Diagnostics 6-35100-A2-GB20-00November 1996The following table describes the meaning and states of the LEDs.TypeLED LED is . . . Indicating . . .DSLLN
Diagnostics 6-45100-A2-GB20-00November 1996Using the Loopback TestsWhen you encounter a problem with a HotWire connection, try to determinewhether the
i5100-A2-GB20-00November 1996ContentsAbout This Guide Purpose and Audience v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostics 6-55100-A2-GB20-00November 1996LAN LoopbackThe LAN loopback enables data received from the CO card ISA bus to be loopedback by the Etherne
Diagnostics 6-65100-A2-GB20-00November 1996Remote LoopbackThe remote loopback enables data received from the CO ISA bus to be loopedback by the firmwa
A-15100-A2-GB20-00November 1996PinoutsAJ1 Ethernet Connector PinoutsPin Number Use1 TX Data +2 TX Data –3 RX Data +4 NC (unused)5 NC (unused)6 RX Dat
B-15100-A2-GB20-00November 1996Installing POTS Splitter atCustomer PremisesBHow to Install the POTS SplitterThe following procedure describes how to
Installing POTS Splitter at Customer Premises B-25100-A2-GB20-00November 1996Use the following procedure to wire the POTS splitter. Procedure1. Attac
Installing POTS Splitter at Customer Premises B-35100-A2-GB20-00November 1996ToSubscriber LoopTo DSL Card inCustomer PCTelephone Network InterfacePOTS
C-15100-A2-GB20-00November 1996Technical SpecificationsCTechnical SpecificationsThe following table lists the technical specifications for the CO car
GL-15100-A2-GB20-00November 1996GlossaryAsymmetric high-bit-rate Digital Subscriber Loop. Provides high-speed digital rates to acustomer premises, whi
IN-15100-A2-GB20-00 November 1996IndexBboard idCO card, 4-8CP card, 4-8Ccentral management utilitymenus, 4-4operation, 3-1, 4-1configurationautom
IndexIN-25100-A2-GB20-00November 1996PPC configuration, 1-3POTS splittercentral office installation, 2-6customer premises installation, B-1part of
Contents ii5100-A2-GB20-00November 19963 Accessing the Central Management Utility Overview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents iii5100-A2-GB20-00November 19966 Diagnostics Overview 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v5100-A2-GB20-00November 1996About This GuidePurpose and AudienceThis guide describes how to install and configure the Central Office (CO)component o
Contents vi5100-A2-GB20-00November 1996Section DescriptionAppendix BInstalling POTS Splitter at Customer Premises.Describes how to install the POTS sp
Comentarios a estos manuales